LoRaWAN Energy Meter
-
LoRaWAN Water Meter
-
LoRaWAN Gas Meter
-
Smart Electricity Meters
-
Prepaid Energy Meter
-
Single Phase Energy Meter
-
Three Phase Energy Meter
-
IOT Smart Water Meter
-
Remote Water Meter
-
Smart Gas Meter
-
AMI Solutions
-
Automatic Meter Reading System
-
Power Distribution Monitoring System
-
Advanced Metering Infrastructure
-
Environmental Monitoring Sensor
Outdoor Indoor PDU Monitoring Software Controlling Management System
Place of Origin | Hubei , China |
---|---|
Brand Name | TimeWave |
Certification | ISO/IEC 20000-1,ISO/IEC 27001,ISO/IEC 9001 |
Minimum Order Quantity | Negotiable |
Price | EXW price US$ 999-9999/ set |
Packaging Details | Customizable packaging |
Delivery Time | 3-5 weeks after receive the payment |
Payment Terms | L/C, T/T |
Supply Ability | Customized products without fixed cycle |
Contact me for free samples and coupons.
Whatsapp:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
If you have any concern, we provide 24-hour online help.
xName | Environment Monitoring Management System | Control Mode | IFSU Centralized Control |
---|---|---|---|
Layout | Cloud Platform, Local Layout | Report | Day,month,year |
Highlight | Outdoor PDU Monitoring Software,Indoor PDU Monitoring Software |
Power Distribution Room Environment Monitoring Controling Management System Outdoor Indoor
- Platform Introduction
According to the actual situation of the distribution room. Independent research and development of TimeWaveCloud distribution room dynamic environment monitoring platform and intelligent energy consumption dynamic environment monitoring unit (iFSU). Realize load operation monitoring such as current, voltage, power and power factor, bus temperature monitoring, cable temperature monitoring, environmental monitoring, access control, air conditioning/fan control, etc. Realize power environment monitoring. Avoid power distribution equipment operation failure caused by uncontrolled operation environment. Extend the service life of the equipment. Ensure the safety of maintenance personnel.
- Introduction to system functions and features
1. Centralized control: iFSU centralized control;
2. Communication mode: Uplink 4G (CAT1)/WLAN, downlink RS485/wireless;
3.Software architecture: B/S architecture+applet/APP+standard API;
4.System integration: Power monitoring, environmental monitoring, security monitoring, bus/cable temperature monitoring are integrated;
5.Real time monitoring: Monitoring and displaying the voltage, current, active power, reactive power, power factor and other operating parameters of the equipment in the power distribution room. And monitoring the environmental operation parameters of the power distribution room;
6. Real time alarm: Alarm for abnormal electrical parameters, temperature, humidity, equipment failure or communication failure;
7. Alarm mode: Pop-up alarm, voice alarm, SMS, WeChat alarm, audible and visual alarm;
8. Data query: Display and query the real-time operation information of the power distribution room;
9. Display mode: Bulletin board display, chart and curve graph display;
10. Operation report: Daily, monthly, annual and operation report;
11. Permission management: Define the permissions of users at different levels to ensure reliable and safe operation;
12. Layout: Cloud platform, local layout;
- Related hardware products
Model Product picture
Major functions Intelligent energy consumption power environment monitoring unit (IFSU)
(TW-IFSU type)Data upload interface:
RJ45 network interface/RS485/CAT1/NB-IOT/LORAWAN.
Switching input: 8 circuits (used for switching value alarm of smog detector, door magnet, water immersion, 220V mains power failure, etc.)DDSD1150/DTSD1150Type
three-phase multi-function
electric watt hour meterIt can measure positive active, negative active electric energy and A/B/C phase electric energy. It can measure total power, total power factor,A/B/C current,A/B/C voltage,A/B/C power factor. Three phase four wire electronic
watt hour meter electronic watt hour meter (DTS150 type)It integrates the functions of metering,alarm,display,switching, monitoring power parameters and overload. The combined active and reactive power can be measured. It has the functions of measuring voltages,currents,power factors,remote centralized meter reading,etc LoRa temperature and humidity sensor
It provides cost-effective LoRaWAN terminal nodes for various work scenarios. It is an IP64 enclosure. Long operation time and low maintenance cost.It is very suitable for outdoor use.
LoRa smog detector
The alarm information that can be sent includes:fire, fault, undervoltage, self inspection, etc. They have universality, extensibility and readability with the communication protocol adopted by the upper layer.
LoRa water immersion detector
It is an alarm device for water leakage detection and is compati with LoRaWAN protocol.The radio transmission is based on LoRa long-distance technology. According to the required behavior and status, the sensor can transmit information and data to the server.
LoRa Cable temperature
measuring deviceA cable temperature measuring devicebased on LoRaWAN. With temperature detection, data reporting, remote monitoring and other functions.
- More features
- User presentation overview: it displays the power consumption profile, site profile, operation status, curve and alarm of all users. Users can be selected from the drop-down box;
- Temperature information: it displays the curve of the ambient temperature in the substation room, the collection time, the average value and other information;
- The system provides the pre alarm configuration function, which can realize the configuration and management of equipment alarm (equipment offline, analog quantity out of limit, temperature out of limit, etc.) strategies. You can set the trigger time of the alarm, the type of the alarm, whether to enable SMS, audible and visual alarm, etc.
- Pre alert Info: The alert information of the site is recorded here. Alarm includes: voltage, current and other line crossing alarm; Switching value alarm; Event alarm; Other alarms. It can record the total number and category of alarms, and filter alarm information according to different search conditions.
- User management: 4 sub items, including user permission setting, operation record, control record and system record. User permissions can be set and changed under high-level user authorization.